6090SFM85Variable Speed Auxiliary
- 9.0L PowerTech™
- 242-410 kW (325-550 hp)
Specifications | ||||
---|---|---|---|---|
John Deere 6090SFM85 Variable Speed Auxiliary |
IMO Tier 2 |
---|
Model | 6090SFM85 | |||
---|---|---|---|---|
Number of cylinders | 6 | |||
Displacement-- L (cu in) | 9.0 (549) | |||
Bore and Stroke-- mm (in) | 118.4 x 136 (4.66 x 5.35) | |||
Engine Type | In-line, 4- Cycle | |||
Aspiration | Air-to-sea water | |||
Length - mm (in) | 1712 (67.4) | |||
Width Maximum - mm (in) | 974 (38.3) | |||
Length to rear face of flywheel housing - mm (in) | 1415 (55.7) | |||
Flywheel housing SAE | 2 | |||
Height - mm (in) | 983 (38.7) | |||
Height, crankshaft centerline to top - mm (in) | 664 (26.1) | |||
Height, crankshaft centerline to bottom - mm (in) | 319 (12.6) | |||
Weight, dry - kg (lb) | 1056 (2328) |
Performance Rating | Power KW (bhp) Rated Speed (rpm) Rated fuel consumption L/hr(gal/hr) |
|||
---|---|---|---|---|
M1 | 242 ( 325 ) 2100 65.4 ( 17.3 ) |
|||
M2 | 280 ( 375 ) 2200 77.6 ( 20.5 ) |
|||
M3 | 317 ( 425 ) 2300 87.4 ( 23.1 ) |
|||
M4 | 373 ( 500 ) 2400 107.1 ( 28.3 ) |
|||
M5 | 410 ( 550 ) 2500 115.6 ( 30.5 ) |
|||
H | 242 (325) 2000 63.2 (16.7) |
M1 - Typical annual usage (hr) | Unrestricted | |||
---|---|---|---|---|
M1 - Typical full-power operation (hr) | Uninterrupted | |||
M1 - Typical load factor | >65% | |||
M2 - Typical annual usage (hr) | 000-5 | |||
M2 - Typical full-power operation (hr) | 16 of each 24 hr | |||
M2 - Typical load factor | <=65% | |||
M3 - Typical annual usage (hr) | 000-4 | |||
M3 - Typical full-power operation (hr) | 4 of each 16 hr | |||
M3 - Typical load factor | <=50% | |||
M4 - Typical annual usage (hr) | 000-3 | |||
M4 - Typical full-power operation (hr) | 1 of each 12 hr | |||
M4 - Typical load factor | <=40% | |||
M5 - Typical annual usage (hr) | 000 hr | |||
M5 - Typical full-power operation (hr) | 0.5 of each 8 hr | |||
M5 - Typical load factor | <=35% | |||
H - Typical annual usage (hr) | Unrestricted | |||
H - Typical full-power operation (hr) | Uninterrupted | |||
H - Typical load factor | ≤ 70% |